What Is Basic Snow Day Programing Honeywell Prowatch

Posted : admin On 07.10.2019
  1. Prowatch 4.3 User Guide
Honeywell

Security Management SuiteHoneywell's Pro-Watch® software is a connected building platform for enterprise and critical infrastructure customers. It helps you meet the most stringent compliance requirements for your industry, and it reduces your total cost of ownership by increasing operator productivity with superior flexibility and scalability.Integration with access control and video systems from Honeywell and third-party manufacturers makes it possible to leverage existing installed hardware as the system expands. Modular hardware and software options make it easy and cost-effective to expand a system to keep up with growing business needs.With Pro-Watch Web Based Client, customers can utilize their existing network infrastructure to provide remote security management for badging, reporting, and alarm and event monitoring.

Less software allows for savings on installation costs and time while continuing to provide optimal security protection.Pro-Watch streamlines tasks with a common user interface to improve operator effectiveness and help organizations minimize training costs. Events may be routed to specific workstations and linked to automated system responses such as camera call-ups and outward notifications.Pro-Watch provides comprehensive options for audit and reporting to address forensics, compliance and business intelligence data mining needs.

The Reporting application includes basic report templates and the capability to generate custom reports. Reports can be exported as XLS, CSV and PDF formats.Pro-Watch provides a solid and proven platform for an intelligent business management solution. It is successfully deployed in enterprises of many sizes and across various vertical applications such as manufacturing facilities, campuses, government facilities and critical infrastructure.

  • The first step to programming a Honeywell programmable thermostat is to press the clock button and use the directional arrow to advance to the correct time of day and then press done, which is located on the lower right-hand side of the unit. Next, press the system button and set the day of the week.
  • Honeywell ProWatch Access and Security Products Price List. PW3KROP302DSW Pro-Watch Professional Starter Kit with OP30 Readers for 2 Doors (1) PWPESW4 Pro-Watch Professional Server Software License (1) PW3K1IC PW-3000 Intelligent Controller (1) PW3K1EN Ethernet Daughterboard.
Day

Request for Quote #Q010814 Highline Community College referred to as HCC would like to add doors to the existing access control system in Bldg. 29 for three classrooms and need electrification modification to the north and south main entry doors, and upgrade the existing 150-user Vista burglar panel in Bldg. The existing system in Bldg. 29 is a Honeywell Prowatch door entry control system which consists of the following: IC board: PW-5000, PW5K1IC Intelligent Controller PW-6000, PW6K1IC Intelligent Controller - the PW-6000 controller configuration and operation is similar to the PW-5000 controller; both use the Pro-Watch at the front end.

Honeywell appreciates your comments about this manual. Please visit us on. That both Snow Day and First Card Rule cannot be enabled at the same time.

The PW6K1IC controller is compatible with the following Honeywell modules: PW5K1R1, PW5K1R2, PW5K1IN, PW5K1OUT, PW6K1R2, PW6K1IN, PW6K1OUT, and PW6KICE. 2 Reader Module: PW-5000, PW5KxR2 - the two reader module provides support for up to two access control doors by providing connections for Wiegand or Clock/Data type readers, supervised inputs and relay outputs. Input Module: PW-5000, PW5KxIN - the input board provides connections for 16 supervised inputs and 2 relay outputs.

Output Module: PW-5000, PW5KxOUT - the output board provides connections to 16 relay outputs. Enclosures: PW-5000, PW5K2ENC1/PW5K2ENC2 - wall mountable secure metal cabinet supporting 9 modules, a 4 AMP power supply and a self-contained replaceable backup battery.

Prowatch 4.3 User Guide

Power Supplies: PW5K2E1PS, HP1204EN - access control power supply and battery charger. It converts AC input into 12 VDC output with 4.0 amps maximum of continuous current.

What Is Basic Snow Day Programing Honeywell Prowatch

It accepts 85VAC to 265VAC input voltage @ 50/60Hz. The power supply has AC Power ON and DC LED indicators and provides AC Fail and Battery Fail supervision when connected to PRO-2200 I/O PFL and auxiliary inputs. Pro-Watch 4.0 Software package.1Burglar Alarm System: FA1600C Vista Panel Bldg.

29; Rooms 202, 203, and 205 The vendor shall provide and install access control system components at three classroom doors. The Honeywell components cannot be substituted but all other components can be as specified or equal but must be compatible with the Honeywell components and existing Prowatch system. The classroom doors need be equipped with two card readers; one to enter the classroom, and one for exiting, door contact, door strike, and REX for each door. There must be free egress via a crash bar or the door handle for each door.

A sounder must be provided and installed at each door to provide local annunciation for times when a valid badge was not presented before the door was opened. Vendor shall install devices at the panel location in Room 142 to accommodate the additions.